Testing Capability

All
No. Testing Object Item/ Parameter Testing Standard (Method)
No. Name
3Military equipment and subsystems36CS116 10kHz~100MHz conducted susceptibility, damped sinusoidal transients, cables and powerleadsElectromagnetic emission and susceptibility requirements for miIitary equipment and subsystems, GJB 151A-97 5.3.13
Measurements of electromagnetic emission and susceptibility for miIitary equipment and subsystems GJB 152A-97 5
37RS101 25Hz~100kHz radiated susceptibility, magnetic fieldElectromagnetic emission and susceptibility requirements for miIitary equipment and subsystems, GJB 151A-97 5.3.17
Measurements of electromagnetic emission and susceptibility for miIitary equipment and subsystems GJB 152A-97 5
38RS103 10kHz~40GHz radiated susceptibility, electric fieldElectromagnetic emission and susceptibility requirements for miIitary equipment and subsystems, GJB 151A-97 5.3.18
Electromagnetic emission and susceptibility requirements for miIitary equipment and subsystems, GJB 151A-97 5.3.18
Measurements of electromagnetic emission and susceptibility for miIitary equipment and subsystems GJB 152A-97 5
Measurements of electromagnetic emission and susceptibility for miIitary equipment and subsystems GJB 152A-97 5
4Naval vessel equipment1CE01 25Hz~10kHz conducted emissions, power leadsRequirements for electromagnetic compatibility of naval ships HJB 34A-2007 10.1
2CE03 10kHz~30MHz conducted emissions, power leadsRequirements for electromagnetic compatibility of naval ships HJB 34A-2007 10.2
3CE06 10kHz~40GHz conducted emissions, antenna terminalRequirements for electromagnetic compatibility of naval ships HJB 34A-2007 10.3
4CS01 25Hz~50kHz conducted susceptibility, power leads and ground wireRequirements for electromagnetic compatibility of naval ships HJB 34A-2007 10.4
5CS03 15kHz~10GHz input terminal intermodulation conduction sensitivityRequirements for electromagnetic compatibility of naval ships HJB 34A-2007 10.5
6CS04 25Hz~20GHz parasitic signal transduction sensitivity at the input endRequirements for electromagnetic compatibility of naval ships HJB 34A-2007 10.6
7CS05 25Hz~20GHz input end cross - modulation conduction sensitivityRequirements for electromagnetic compatibility of naval ships HJB 34A-2007 10.7
8CS06 conducted susceptibility, transients, power leadsRequirements for electromagnetic compatibility of naval ships HJB 34A-2007 10.8
9CS09 50Hz~100kHz circulatory conduction sensitivityRequirements for electromagnetic compatibility of naval ships HJB 34A-2007 10.9
10CS10 10kHz~400MHz conducted susceptibility, bulk cable injectionRequirements for electromagnetic compatibility of naval ships HJB 34A-2007 10.10
11CS11 10kHz~100MHz conducted susceptibility, damped sinusoidal transients, cables and powerleadsRequirements for electromagnetic compatibility of naval ships HJB 34A-2007 10.11
12CS12 electrostatic discharge sensitivityRequirements for electromagnetic compatibility of naval ships HJB 34A-2007 10.12