Testing Capability

Non-metallic material for wire and cable
No. Testing Object Item/ Parameter Testing Standard (Method)
No. Name
3Insulating materials for shipboard and offshore units, power, control, instrumentation, telecommunication and data cables3Mechanical properties testCommon test methods for insulating and sheathing materials of electric and optical cables - Part 11:Methods for general application - Measurement of thickness and overall dimensions - Tests for determining the mechanical properties GB/T 2951.11-2008
4Determining the mechanical properties after thermal ageing in airovenCommon test methods for insulating and sheathing materials of electric and optical cables - Part 12:Methods for general application - Thermal ageing methodsGB/T 2951.12-2008
Common test methods for insulating and sheathing materials of electric and optical cables - Part 11:Methods for general application - Measurement of thickness and overall dimensions - Tests for determining the mechanical properties GB/T 2951.11-2008
5Determining the mechanical properties after thermal ageing in an air bombCommon test methods for insulating and sheathing materials of electric and optical cables - Part 12:Methods for general application - Thermal ageing methods GB/T 2951.12-2008
Common test methods for insulating and sheathing materials of electric and optical cables - Part 11:Methods for general application - Measurement of thickness and overall dimensions - Tests for determining the mechanical properties GB/T 2951.11-2008
6Pressure test at high temperatureCommon test methods for insulating and sheathing materials of electric and optical cables - Part 31:Methods specific to PVC compounds - Pressure test at high temperature - Test for resistance to cracking GB/T 2951.31-2008
7Hot set testCommon test methods for insulating and sheathing materials of electric and optical cables - Part 21:Methods specific to elastomeric compounds - Ozone resistance, hot set and mineral oil immersion tests GB/T 2951.21-2008
8Test for resistance to crackingCommon test methods for insulating and sheathing materials of electric and optical cables - Part 31:Methods specific to PVC compounds - Pressure test at high temperature - Test for resistance to cracking GB/T 2951.31-2008
9Loss of mass testCommon test methods for insulating and sheathing materials of electric and optical cables - Part 32:Methods specific to PVC ompounds - Loss of mass test - Thermal stability test GB/T 2951.32-2008
10Determination of acidity by pH measurementand conductivityTest on gases evolved during combustion of materials from cables - Part 2: Determination of acidity (by pH measurement) and conductivity IEC 60754-2:2011
11Elasticity modulusInsulating materials for shipboard and offshore units, power, control, instrumentation, telecommunication and data cables GB/T 17557-2010 Appendix B
4Semi-conductive shielding compound for power cables of rated voltages up to and including 35kV1Appearance inspectionSemi-conductive shielding compound for power cables of rated voltages up to and including 35kV JB/T 10738-2007 5.1
2Tensile strength and elongation testPlastics—Determination of tensile properties—Part 3:Test conditions for films and sheets GB/T 1040.3-2006
3Determining the mechanical properties after thermal ageing in airovenCommon test methods for insulating and sheathing materials of electric and optical cables - Part 12:Methods for general application - Thermal ageing methods GB/T 2951.12-2008
4Hot set testCommon test methods for insulating and sheathing materials of electric and optical cables - Part 21:Methods specific to elastomeric compounds - Ozone resistance, hot set and mineral oil immersion tests GB/T 2951.21-2008
5Volume resistivityTest methods for electrical properties of electric cables and wires - Part 3:Test of volume resistivity of semi-conducting rubbers and plastics GB/T 3048.3-2007
6Peel strengthSemi-conductive shielding compound for power cables of rated voltages up to and including 35kV JB/T 10738-2007 Appendix B
7Peel strength after thermal ageing in airovenSemi-conductive shielding compound for power cables of rated voltages up to and including 35kV JB/T 10738-2007 Appendix B
8DensityPlastics - Methods for determining the density of non-cellular plastics - Part 1: Immersion method, liquid pyknometer method and titration method GB/T 1033.1-2008
Plastics - Methods for determining the density of non-cellular plastics - Part 1: Immersion method, liquid pyknometer method and titration method GB/T 1033.1-2008