Testing Capability

Wire and Cable
No. Testing Object Item/ Parameter Testing Standard (Method)
No. Name
5Insulation and sheath material of cable and optical cable9Ageing in an air bombElectric and optical fibre cables - Test methods for non-metallic materials - Part 412: Miscellaneous tests - Thermal ageing methods - Ageing in an air bomb EN 60811-412:2012
10Measurement for determining the densityCommon test methods for insulating and sheathing materials of electric and optical cables - Part 13:Methods for general application - Measurement for determining the density - Water absorption tests - Shrinkage test GB/T 2951.13-2008IEC 60811-1-3:2001 8.3
Electric and optical fibre cables - Test methods for non-metallic materials - Part 606: Physical tests - Methods for determining the density IEC 60811-606:2012
Electric and optical fibre cables - Test methods for non-metallic materials - Part 606: Physical tests - Methods for determining the density EN 60811-606:2012
11Water absorption testsCommon test methods for insulating and sheathing materials of electric and optical cables - Part 13:Methods for general application - Measurement for determining the density - Water absorption tests - Shrinkage test GB/T 2951.13-2008IEC 60811-1-3:2001 9.1,9.2
12Electric and optical fibre cables - Test methods for non-metallic materials - Part 402: Miscellaneous tests - Water absorption tests IEC 60811-402:2012
Electric and optical fibre cables - Test methods for non-metallic materials - Part 402: Miscellaneous tests - Water absorption tests EN 60811-402:2012
13Shrinkage testCommon test methods for insulating and sheathing materials of electric and optical cables - Part 13:Methods for general application - Measurement for determining the density - Water absorption tests - Shrinkage test GB/T 2951.13-2008IEC 60811-1-3:2001 Chapter10,Chapter11
14Shrinkage test for insulationsElectric and optical fibre cables - Test methods for non-metallic materials - Part 502: Mechanical tests - Shrinkage test for insulations IEC 60811-502:2012
Electric and optical fibre cables - Test methods for non-metallic materials - Part 502: Mechanical tests - Shrinkage test for insulations EN 60811-502:2012
15Shrinkage test for sheathsElectric and optical fibre cables - Test methods for non-metallic materials - Part 503: Mechanical tests - Shrinkage test for sheaths IEC 60811-503:2012
Electric and optical fibre cables - Test methods for non-metallic materials - Part 503: Mechanical tests - Shrinkage test for sheaths EN 60811-503:2012
16Test at low temperatureCommon test methods for insulating and sheathing materials of electric and optical cables - Part 14:Methods for general application - Test at low temperature GB/T 2951.14-2008
IEC 60811-1-4:1985+A1:1993+A2:2001
17Bending tests at low temperature for insulation and sheathsElectric and optical fibre cables - Test methods for non-metallic materials - Part 504: Mechanical tests - Bending tests at low temperature for insulation and sheaths IEC 60811-504:2012
Electric and optical fibre cables - Test methods for non-metallic materials - Part 504: Mechanical tests - Bending tests at low temperature for insulation and sheaths EN 60811-504:2012
18Elongation at low temperature for insulations and sheathsElectric and optical fibre cables - Test methods for non-metallic materials - Part 505: Mechanical tests - Elongation at low temperature for insulations and sheaths IEC 60811-505:2012
Electric and optical fibre cables - Test methods for non-metallic materials - Part 505: Mechanical tests - Elongation at low temperature for insulations and sheaths EN 60811-505:2012
19Impact test at low temperature for insulations and sheathsElectric and optical fibre cables. Test methods for non-metallic materials. Part 506:Mechanical tests. Impact test at low temperature for insulations and sheaths IEC 60811-506:2012
Electric and optical fibre cables - Test methods for non-metallic materials - Part 506: Mechanical tests - Impact test at low temperature for insulations and sheaths EN 60811-506:2012