| 2 | General electronic and electrical products | 1 | Conducted disturbance measurements(AN) | Specification for radio disturbance and immunity measuring apparatus and methods--Part 2-1: Methods of measurement of disturbances and immunity-- Conducted disturbance measurements GB/T 6113.201-2018 7.3.2 |
| Specification for radio disturbance and immunity measuring apparatus and methods--Part 2-1: Methods of measurement of disturbances and immunity-- Conducted disturbance measurements CISPR 16-2-1:2017 7 |
| 2 | Conducted disturbance measurements(Voltage probe) | Specification for radio disturbance and immunity measuring apparatus and methods--Part 2-1: Methods of measurement of disturbances and immunity-- Conducted disturbance measurements GB/T 6113.201-2018 7.3.3 |
| Specification for radio disturbance and immunity measuring apparatus and methods--Part 2-1: Methods of measurement of disturbances and immunity-- Conducted disturbance measurements CISPR 16-2-1:2017 7 |
| 3 | Conducted disturbance measurements(Current probe) | Specification for radio disturbance and immunity measuring apparatus and methods--Part 2-1: Methods of measurement of disturbances and immunity-- Conducted disturbance measurements GB/T 6113.201-2018 7.3.4 |
| Specification for radio disturbance and immunity measuring apparatus and methods--Part 2-1: Methods of measurement of disturbances and immunity-- Conducted disturbance measurements CISPR 16-2-1:2017 7 |
| 4 | Discontinuous disturbances | Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission GB 4343.1-2018 4.2 |
| Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission CISPR 14-1:2016EN 55014-1:2017 4.4 |
| 5 | Disturbance power | Specification for radio disturbance and immunity measuring apparatus and methods--Part 2-2: Methods of measurement of disturbances and immunity-- Measurement of disturbance power GB/T 6113.202-2018 |
| Specification for radio disturbance and immunity measuring apparatus and methods--Part 2-2: Methods of measurement of disturbances and immunity-- Measurement of disturbance power CISPR 16-2-2:2010 |
| 6 | Radiated disturbance(30MHz~1GHzSAC measurements) | Specification for radio disturbance and immunity measuring apparatus and methods--Part 2-3: Methods of measurement of disturbances and immunity-- Radiated disturbance measurements GB/T 6113.203-2016 7.3 |
| Specification for radio disturbance and immunity measuring apparatus and methods--Part 2-3: Methods of measurement of disturbances and immunity-- Radiated disturbance measurements CISPR 16-2-3:2016 7.3 |
| 7 | Radiated disturbance(30MHz~1GHzFAR measurements) | Specification for radio disturbance and immunity measuring apparatus and methods--Part 2-3: Methods of measurement of disturbances and immunity-- Radiated disturbance measurements GB/T 6113.203-2016 7.4 |
| Specification for radio disturbance and immunity measuring apparatus and methods--Part 2-3: Methods of measurement of disturbances and immunity-- Radiated disturbance measurements CISPR 16-2-3:2016 7.4 |
| 8 | Radiated immunity (80MHz~1GHz) | Specification for radio disturbance and immunity measuring apparatus and methods--Part 2-3: Methods of measurement of disturbances and immunity-- Radiated disturbance measurements GB/T 6113.203-2016 7.5 |
| Specification for radio disturbance and immunity measuring apparatus and methods--Part 2-3: Methods of measurement of disturbances and immunity-- Radiated disturbance measurements CISPR 16-2-3:2016 7.5 |
| 9 | Radiated disturbance measurements(1GHz~18GHz) | Specification for radio disturbance and immunity measuring apparatus and methods--Part 2-3: Methods of measurement of disturbances and immunity-- Radiated disturbance measurements GB/T 6113.203-2016 7.6 |
| Specification for radio disturbance and immunity measuring apparatus and methods--Part 2-3: Methods of measurement of disturbances and immunity-- Radiated disturbance measurements CISPR 16-2-3:2016 7.6 |
| 10 | Radiated disturbances | Electromagnetic compatibility(EMC) - Generic standards - Emission standard for residential, commercial and light-industrial environments GB/T 17799.3-2012 11 |
| Electromagnetic compatibility(EMC) -Part 6-3: Generic standards - Emission standard for residential, commercial and light-industrial environments IEC 61000-6-3:2011 11 |